1.
Glob Health Med ; 4(5): 289-291, 2022 Oct 31.
Article in English | MEDLINE | ID: covidwho-2115753

ABSTRACT

Due to the coronavirus disease 2019 (COVID-19) pandemic, we have been conducting polymerase chain reaction (PCR) testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at this facility since March 2020. In the early days, the PCR testing system had limited capabilities, so testing had to be conducted manually and only a few tests were conducted. Moreover, we lacked sufficient experience to conduct PCR testing manually, so we struggled with the manual work, which required intense concentration, and we felt pressured not to make mistakes such as allowing contamination. Since we introduced upgraded equipment, new methods, and additional staff for testing and we cooperated with the clinical technologist on the night shift in the Emergency Department, we are currently able to conduct urgent PCR testing on more than 2,000 specimens per month 24 hours a day. We will continue to meet new needs for COVID-19 treatment with the cooperation of other departments.

2.
Jpn J Infect Dis ; 75(3): 309-313, 2022 May 24.
Article in English | MEDLINE | ID: covidwho-1865651

ABSTRACT

Several commercial nucleic acid amplification tests (NAATs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed. We used 6 kits available in Japan in 13 NAAT-positive specimens with crossing point values >36 and 7 NAAT-negative specimens from patients with coronavirus disease 2019 (COVID-19), and their results were compared. Specimens positive in ≥2 assays were considered true-positive and examined for concordance with the specimen results. The SARS-CoV-2 Detection Kit -Multi- (Toyobo M; Toyobo, Osaka, Japan) using extracted RNA had the highest concordance (κ = 1.00). This was followed by Cobas® SARS-CoV-2 (Roche, Basel, Switzerland) (κ = 0.79). There was a weak correlation between the number of negative results for each kit and the number of days between onset and testing (Spearman rank correlation: ρ = 0.44; P < 0.05). We believe that the variations in results among kits for specimens with low viral loads should not be problematic when these kits are used for screening infectious patients because these variations are more likely to be observed in specimens tested many days after onset (i.e., those that have lost their infectivity). However, it may be better to use a test for suspected late-stage COVID-19 with a low viral load, such as Toyobo M or Cobas.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Negative Results , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/genetics , Sensitivity and Specificity
3.
Infect Dis (Lond) ; 53(8): 581-589, 2021 08.
Article in English | MEDLINE | ID: covidwho-1147914

ABSTRACT

BACKGROUND: The current gold standard in coronavirus disease (COVID-19) diagnostics is the real-time reverse transcription-polymerase chain reaction (RT-PCR) assay for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in nasopharyngeal swab (NPS) samples. Alternatively, nasal swab (NS) or saliva swab (SS) specimens are used, although available data on test accuracy are limited. We examined the diagnostic accuracy of NPS/NS/SS samples for this purpose. METHODS: Ten patients were included after being tested positive for SARS-CoV-2 RT-PCR in NPS samples according to the National Institute of Infectious Disease guidelines. In comparison with this conventional diagnostic method, NPS/NS/SS samples were tested using the cobas 6800 systems RT-PCR device. To investigate the usefulness of the cobas method and the difference among sample types, the agreement and sensitivity were calculated. Five to six samples were collected over a total period of 5-6 d from each patient. RESULTS: Fifty-seven sets of NPS/NS/SS samples were collected, of which 40 tested positive for COVID-19 by the conventional method. Overall, the concordance rates using the conventional method were 86.0%/70.2%/54.4% for NPS/NS/SS samples (cobas); however, for samples collected up to and including on Day 9 after disease onset (22 negative and one positive specimens), the corresponding rates were 95.7%/87.0%/65.2%. The overall sensitivity estimates were 100.0%/67.5%/37.5% for NPS/NS/SS samples (cobas). For samples up to 9 d after onset, the corresponding values were 100.0%/86.4%/63.6%. CONCLUSIONS: NS samples are more reliable than SS samples and can be an alternative to NPS samples. They can be a useful diagnostic method in the future.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Nasopharynx , Reverse Transcriptase Polymerase Chain Reaction , Saliva , Specimen Handling
4.
Glob Health Med ; 3(2): 107-111, 2021 Apr 30.
Article in English | MEDLINE | ID: covidwho-1128386

ABSTRACT

The quantitative reverse transcription polymerase chain reaction method using nasopharyngeal swabs (NPS RT-qPCR) is regarded as the reference standard for diagnosing coronavirus disease 2019 (COVID-19). However, when using NPS RT-qPCR at busy airport quarantine stations, there are constraints on testing capacity, time, travelerstolerance, and availability of personal protective equipment for quarantine officers. A feasible alternative is therefore needed to test incoming travelers, especially when passenger numbers increase with the resumption of business, tourism, and economic activities. To explore alternatives to NPS RT-qPCR, we collected nasopharyngeal, anterior nasal, and saliva samples chronologically over days 1-7 from asymptomatic COVID-19 air travelers who were under quarantine at a designated facility, and we then compared test results for 9 different methods, comprising RT-qPCR (including the reference method), loop-mediated isothermal amplification (LAMP), and qualitative and quantitative antigen testing. We evaluated sensitivity for 97 person-day samples independently to evaluate asymptomatic travelers regardless of their testing date and period of asymptomatic status upon entry. Sensitivity of the different tests varied from 46.6% to 81.0%, but this was improved from 72.7% to 100.0% when the viral load was > 10 4 copies/sample on NPS RT-qPCR. Thus, most high-risk asymptomatic travelers with higher viral load would be detected by the tests evaluated. Quantitative antigen testing using saliva samples showed 90.9% sensitivity and provided quicker results, and should be an acceptable alternative to NPS RT-qPCR at busy airport quarantine stations. We discuss the implications of our exploratory findings for establishing a comprehensive and feasible testing strategy for COVID-19 among air passengers.

SELECTION OF CITATIONS
SEARCH DETAIL